Sigma10

Geberit Sigma10 Touchless Toilet Flush Plate - Mains / Battery Operated - 115.907.X/115.908.X

RRP £556.67

Our Price £417.50
Need to ask a question ? 01524 841087 Call: Contact us for Delivery Timescales on this item

Available Options:

* Required Fields

Quantity:

Details

 
PLEASE NOTE THAT FOR NEW INSTALLS YOU MUST PURCHASE THE INSTALLATION PACK 115.861.00.1
 
hide
Application purpose
  • For private and semi-public areas
  • For releasing a dual flush
  • For solid and drywall construction
  • For touchless flush actuation of Geberit Sigma concealed cisterns 12 cm
  • Not suitable for use with Geberit inserts for in-cistern block
  • Not suitable for less-abled installation
hide
Characteristics
  • Touchless manual flush actuation
  • Automatic flush actuation
  • Touchless flush actuation for single or dual flush by moving hand toward sensor
  • Power supply via power supply unit
  • External power supply unit
  • Transformation of mains voltage to extra-low voltage, 4.1 V DC
  • Operation with extra-low voltage, no mains voltage in cistern
  • With push-fit connection with cross-polarity protection
  • Infrared user detection with background fade-out
  • Self-adjusting IR sensor
  • Reliable IR distance detection
  • Interval flush preset
  • Adjustable interval flush
  • Pre-flush can be set
  • Minimum detection time can be set
  • Compatible with Geberit Service Handy
  • Functions can be set and queried with the Geberit Service Handy
  • Flush actuation can be deactivated via Geberit Clean Handy
  • Low-noise lifting mechanism
  • Electrical lifting device, self-calibrating
  • Easy maintenance and cleaning
hide
Technical data
Protection degree IP45  
Nominal voltage 85–240 V AC  
Mains frequency 50–60 Hz  
Operating voltage 4.1 V DC  
Interval flush, adjustment range 1–168 h  
Interval flush, factory setting 24 h  
Detection time, adjustment range 1–60 s  
Detection time, factory setting 7 s

 

Battery type LR20  
Operating voltage 3 V DC  
Interval flush, adjustment range 1–168 h  
Interval flush, factory setting 24 h  
Detection time, adjustment range 1–60 s  
Detection time, factory setting 7 s